nt-power-mgmt-fix-20040617

The fixed timeout of 19 seconds was too short.  Should be set to the
value of HardDeadtimeout as set by cm_conn.c.  The failure to specify
an adequate timeout value prevented successful Hibernation and Standby
mode access when network connectivity was not available.