srcdir=@srcdir@
include @TOP_OBJDIR@/src/config/Makefile.config
+INSTALL = @INSTALL@
+INSTALL_DATA = @INSTALL_DATA@
+INSTALL_PROGRAM = @INSTALL_PROGRAM@
+INSTALL_SCRIPT = @INSTALL_SCRIPT@
INCLS=${TOP_INCDIR}/afs/afsint.h \
${TOP_INCDIR}/afs/cmd.h \
cacheout.o: cacheout.c
-${DEST}/bin/fs ${DEST}/root.server/usr/afs/bin/fs: fs
- ${INSTALL} -s $? $@
-
-${DEST}/bin/livesys: livesys
- ${INSTALL} -s $? $@
-
-${DEST}/bin/up: up
- ${INSTALL} -s $? $@
-
-${DEST}/etc/fstrace: fstrace
- ${INSTALL} -s $? $@
-
-${DEST}/bin/cmdebug: cmdebug
- ${INSTALL} -s $? $@
-
-
up.o: up.c AFS_component_version_number.c
fstrace: fstrace.o
case ${SYS_NAME} in \
- pmax_ul43 | pmax_ul43a ) \
- ${CC} ${CFLAGS} -o fstrace fstrace.o ${TOP_LIBDIR}/libsys.a ${TOP_LIBDIR}/libcmd.a ${TOP_LIBDIR}/util.a /usr/lib/libi.a ;; \
sun4_411 | sun4c_411 | sun4m_412 ) \
${CCXPG2} ${CFLAGS} -o fstrace fstrace.o ${TOP_LIBDIR}/libsys.a ${TOP_LIBDIR}/libcmd.a ${TOP_LIBDIR}/util.a ;; \
sun*_4* ) \
hp700_ux100 | hp800_ux100 | hp?00_ux10? | hp_ux10? | hp_ux11?) \
${CC} -I${TOP_OBJDIR}/src/config -o fstrace fstrace.o ${TOP_LIBDIR}/libsys.a ${TOP_LIBDIR}/libcmd.a ${TOP_LIBDIR}/util.a ;; \
* ) \
- ${CC} ${CFLAGS} -o fstrace fstrace.o ${TOP_LIBDIR}/libsys.a ${TOP_LIBDIR}/libcmd.a ${TOP_LIBDIR}/util.a ;; \
+ ${CC} ${CFLAGS} -o fstrace fstrace.o ${TOP_LIBDIR}/libsys.a ${TOP_LIBDIR}/libcmd.a ${TOP_LIBDIR}/util.a ${XLIBS} ;; \
esac
cmdebug.o: cmdebug.c ${INCLS} AFS_component_version_number.c
cmdebug: cmdebug.o ${CMLIBS}
$(CC) -o cmdebug cmdebug.o ${CFLAGS} ${CMLIBS} ${XLIBS}
+dedebug.o: dedebug.c ${INCLS} AFS_component_version_number.c
+
+dedebug: dedebug.o ${CMLIBS}
+ $(CC) -o dedebug dedebug.o ${CFLAGS} ${CMLIBS} ${XLIBS}
+
#
kdump-build: kdump.c ${INCLS} AFS_component_version_number.c
$(MAKE) kdump kdump64
touch kdump-build
-
+
#
# Build targets - one for each type of kdump build process we have
#
-kdump:
+kdump: kdump.o
-set -x; \
case ${SYS_NAME} in \
sun4c_51 | sun4c_52 | sun4m_51 | sun4m_52 | sun4c_53 | sun4m_53 | sun4_53 | sun4_54 | sun4c_54 | sun4m_54 | sunx86_5? ) \
${CC} -o kdump kdump.o ${TOP_LIBDIR}/libcmd.a ${TOP_LIBDIR}/util.a /usr/lib/libkvm.a -lelf ${XLIBS} ;; \
- sun*_5? ) \
+ sun*_5? | sun*_5?? ) \
${CC} -o kdump kdump.o ${TOP_LIBDIR}/libcmd.a ${TOP_LIBDIR}/util.a ${XLIBELFA} ${XLIBKVM} ${XLIBS} ;; \
sgi_6? ) \
for f in ../libafs/STATIC.IP*/CPU_KDEFS; \
-o kdump.$$IP kdump.$$IP.o \
${TOP_LIBDIR}/libcmd64.a -lelf \
;; \
- *) ${CC} ${XCFLAGS} \
+ *) ${CC} ${XCFLAGS} ${ARCHFLAGS} \
$$CPU_KDEFS \
-o kdump.$$IP kdump.$$IP.o \
${TOP_LIBDIR}/libcmd.a -lelf \
;; \
esac || exit $$? ; \
done ;; \
+ *linux26* | *linux_26* ) \
+ touch kdump ;; \
*alpha_linux* ) \
$(MAKE) kdump-alpha_linux-@LINUX_VERSION@ ;; \
*linux* ) \
alpha_osf1 | alpha_osf20 | alpha_osf30 | alpha_osf32 | alpha_osf32c | alpha_dux??) \
${CC} -o kdump kdump.o ${TOP_LIBDIR}/libcmd.a ${TOP_LIBDIR}/util.a ${XLIBS} -ll -lmld;; \
ncrx86_* ) ${CC} -o kdump kdump.o ${TOP_LIBDIR}/libcmd.a ${TOP_LIBDIR}/util.a -lelf ${XLIBS} ;; \
- *nbsd*) touch kdump ;; \
+ *bsd*) touch kdump ;; \
* ) ${CC} -o kdump kdump.o ${TOP_LIBDIR}/libcmd.a ${TOP_LIBDIR}/util.a ${XLIBS} ;; \
esac
kdump64:
-set -x; \
case ${SYS_NAME} in \
- sun4x_5[789] | hp_ux11* |sunx86_5[789] ) \
- ${CC} ${XCFLAGS64} -o ${KDUMP64} ${KDUMP64}.o ${TOP_LIBDIR}/libcmd64.a ${XLIBELFA} ${XLIBKVM} ${XLIBS} ;; \
+ sun4x_5[789] | sun4x_510 | hp_ux11* | sunx86_5[789] | sunx86_510 ) \
+ $(MAKE) kdump64.o ; \
+ ${CC} ${XCFLAGS64} -o kdump64 kdump64.o ${TOP_LIBDIR}/libcmd64.a ${XLIBELFA} ${XLIBKVM} ${XLIBS} ;; \
esac
kdump.o: kdump.c ${INCLS} AFS_component_version_number.c
-set -x; \
case ${SYS_NAME} in \
+ *linux26* | *linux_26* ) \
+ touch kdump.o ;; \
alpha_linux* ) \
$(MAKE) kdump-alpha_linux-${LINUX_VERSION}.o ;; \
*linux* ) \
${KERN_DBG} ${KERN_OPTMZ} -I${TOP_INCDIR} \
-I${TOP_OBJDIR}/src/config \
$$CPU_KDEFS \
- ${XCFLAGS} -DAFS_32BIT_KERNEL_ENV \
+ ${XCFLAGS} ${ARCHFLAGS} -DAFS_32BIT_KERNEL_ENV \
-c ${srcdir}/kdump.c -o kdump.$$IP.o \
;; \
esac || exit $$?; \
done \
;; \
- *nbsd*) \
+ *bsd*) \
touch kdump.o ;; \
*) \
${CC} ${KERN_DBG} ${KERN_OPTMZ} -I${TOP_SRCDIR} -I${TOP_INCDIR}/afs \
- -I${TOP_OBJDIR}/src/config -I${TOP_INCDIR} ${XCFLAGS} \
+ -I${TOP_OBJDIR}/src/config -I${TOP_OBJDIR}/src -I${TOP_INCDIR} ${XCFLAGS} ${ARCHFLAGS} \
-o kdump.o -c ${srcdir}/kdump.c ;; \
esac ;
kdump64.o : kdump.c ${INCLS} AFS_component_version_number.c
-set -x; \
case ${SYS_NAME} in \
- sun4x_5[789] | hp_ux11* |sunx86_5[789] ) \
+ sun4x_5[789] | sun4x_510 | hp_ux11* | sunx86_5[789] | sunx86_510 ) \
${CC} ${KERN_DBG} ${KERN_OPTMZ} -I${TOP_SRCDIR} -I${TOP_INCDIR}/afs \
- -I${TOP_OBJDIR}/src/config -I${TOP_INCDIR} ${XCFLAGS64} \
+ -I${TOP_OBJDIR}/src/config -I${TOP_OBJDIR}/src -I${TOP_INCDIR} ${XCFLAGS64} \
-o kdump64.o -c ${srcdir}/kdump.c ;; \
esac
-I${TOP_OBJDIR}/src/afs/${MKAFS_OSTYPE} \
-I${TOP_OBJDIR}/src/config -I${TOP_OBJDIR}/src/libafs/afs \
-I${TOP_SRCDIR} -I${TOP_SRCDIR}/afs/${MKAFS_OSTYPE} \
- -I${TOP_INCDIR} ${XCFLAGS} -o kdump-linux-${LINUX_VERSION}.o \
+ -I${TOP_INCDIR} ${XCFLAGS} ${ARCHFLAGS} -o kdump-linux-${LINUX_VERSION}.o \
-c ${srcdir}/kdump.c
kdump-linux-@LINUX_VERSION@: kdump-linux-@LINUX_VERSION@.o
-I${TOP_OBJDIR}/src/afs/${MKAFS_OSTYPE} \
-I${TOP_OBJDIR}/src/config -I${TOP_OBJDIR}/src/libafs/afs \
-I${TOP_SRCDIR} -I${TOP_SRCDIR}/afs/${MKAFS_OSTYPE} \
- -I${TOP_INCDIR} ${XCFLAGS} -mno-fp-regs -ffixed-8 \
+ -I${TOP_INCDIR} ${XCFLAGS} ${ARCHFLAGS} -mno-fp-regs -ffixed-8 \
-o kdump-alpha_linux-${LINUX_VERSION}.o -c ${srcdir}/kdump.c ;; \
kdump-alpha_linux-@LINUX_VERSION@: kdump-alpha_linux-@LINUX_VERSION@.o
${TOP_LIBDIR}/libcmd.a ${TOP_LIBDIR}/util.a ${XLIBS}
#
-# kdump install targets
+# Install targets
#
-${DEST}/etc/kdump: kdump-build
+install: kdump-build fs livesys up fstrace cmdebug
+ ${INSTALL} -d ${DESTDIR}${bindir}
+ ${INSTALL} -d ${DESTDIR}${afssrvbindir}
+ ${INSTALL} -d ${DESTDIR}${sbindir}
+ ${INSTALL_PROGRAM} fs ${DESTDIR}${bindir}/fs
+ ${INSTALL_PROGRAM} livesys ${DESTDIR}${bindir}/livesys
+ ${INSTALL_PROGRAM} fs ${DESTDIR}${afssrvbindir}/fs
+ ${INSTALL_PROGRAM} up ${DESTDIR}${bindir}/up
+ ${INSTALL_PROGRAM} fstrace ${DESTDIR}${sbindir}/fstrace
+ ${INSTALL_PROGRAM} cmdebug ${DESTDIR}${bindir}/cmdebug
+ -set -x; \
+ case ${SYS_NAME} in \
+ sgi_6? ) \
+ ${INSTALL_SCRIPT} kdump.sh.sgi_ipnos ${DESTDIR}${sbindir}/kdump; \
+ ln -fs kdump ${DESTDIR}${sbindir}/kdump32; \
+ ln -fs kdump.IP20 ${DESTDIR}${sbindir}/kdump.IP22; \
+ ln -fs kdump.IP20 ${DESTDIR}${sbindir}/kdump.IP32; \
+ for f in kdump.IP??; \
+ do ${INSTALL_PROGRAM} $$f ${DESTDIR}${sbindir}/$$f || exit $$? ; \
+ done ;; \
+ sun*_5[789] | sun*_510 ) \
+ ${INSTALL_SCRIPT} kdump.sh.solaris7 ${DESTDIR}${sbindir}/kdump32; \
+ ${INSTALL_PROGRAM} kdump-build ${DESTDIR}${sbindir}/kdump;; \
+ *linux26* | *linux_26* ) \
+ ;; \
+ *linux* ) \
+ ${INSTALL_SCRIPT} kdump.sh.linux ${DESTDIR}${sbindir}/kdump; \
+ ${INSTALL_PROGRAM} kdump-build ${DESTDIR}${sbindir}/kdump ;; \
+ hp_ux11* ) \
+ ${INSTALL_SCRIPT} kdump.sh.hp_ux11 ${DESTDIR}${sbindir}/kdump; \
+ ${INSTALL_PROGRAM} kdump-build ${DESTDIR}${sbindir}/kdump ;; \
+ *) \
+ ${INSTALL_PROGRAM} kdump-build ${DESTDIR}${sbindir}/kdump ;; \
+ esac
+ if [ -f kdump64 ]; then \
+ ${INSTALL_PROGRAM} kdump64 ${DESTDIR}${sbindir}/kdump; \
+ fi
+
+dest: kdump-build fs livesys up fstrace cmdebug
+ ${INSTALL} -d ${DEST}/bin
+ ${INSTALL} -d ${DEST}/etc
+ ${INSTALL} -d ${DEST}/root.server/usr/afs/bin
+ ${INSTALL_PROGRAM} fs ${DEST}/bin/fs
+ ${INSTALL_PROGRAM} livesys ${DEST}/bin/livesys
+ ${INSTALL_PROGRAM} fs ${DEST}/root.server/usr/afs/bin/fs
+ ${INSTALL_PROGRAM} up ${DEST}/bin/up
+ ${INSTALL_PROGRAM} fstrace ${DEST}/etc/fstrace
+ ${INSTALL_PROGRAM} cmdebug ${DEST}/bin/cmdebug
-set -x; \
case ${SYS_NAME} in \
sgi_6? ) \
- ${INSTALLex} -f ${srcdir}/kdump.sh.sgi_ipnos ${DEST}/etc/kdump; \
+ ${INSTALL_SCRIPT} ${srcdir}/kdump.sh.sgi_ipnos ${DEST}/etc/kdump; \
ln -fs kdump ${DEST}/etc/kdump32; \
ln -fs kdump.IP20 ${DEST}/etc/kdump.IP22; \
ln -fs kdump.IP20 ${DEST}/etc/kdump.IP32; \
for f in kdump.IP??; \
- do ${INSTALL} -s $$f ${DEST}/etc/$$f || exit $$? ; \
+ do ${INSTALL_PROGRAM} $$f ${DEST}/etc/$$f || exit $$? ; \
done ;; \
- sun*_5[789] ) \
- ${INSTALLex} -f ${srcdir}/kdump.sh.solaris7 ${DEST}/etc/kdump; \
- ${INSTALL} -s -f $? $@;; \
+ sun*_5[789] | sun*_510 ) \
+ ${INSTALL_SCRIPT} ${srcdir}/kdump.sh.solaris7 ${DEST}/etc/kdump; \
+ ${INSTALL_PROGRAM} ${srcdir}/kdump ${DEST}/etc/kdump32;; \
+ *linux26* | *linux_26* ) \
+ ;; \
*alpha_linux* ) \
- ${INSTALLex} -f ${srcdir}/kdump.sh.linux ${DEST}/etc/kdump; \
- ${INSTALL} -s kdump-alpha_linux-${LINUX_VERSION} $@ ;; \
+ ${INSTALL_SCRIPT} ${srcdir}/kdump.sh.linux ${DEST}/etc/kdump; \
+ ${INSTALL_PROGRAM} kdump-alpha_linux-${LINUX_VERSION} ${DEST}/etc/kdump-${LINUX_VERSION} ;; \
*linux* ) \
- ${INSTALLex} -f ${srcdir}/kdump.sh.linux ${DEST}/etc/kdump; \
- ${INSTALL} -s kdump-linux-${LINUX_VERSION} $@ ;; \
+ ${INSTALL_SCRIPT} ${srcdir}/kdump.sh.linux ${DEST}/etc/kdump; \
+ ${INSTALL_PROGRAM} kdump-linux-${LINUX_VERSION} ${DEST}/etc/kdump-${LINUX_VERSION} ;; \
hp_ux11* ) \
- ${INSTALLex} -f ${srcdir}/kdump.sh.hp_ux11 ${DEST}/etc/kdump; \
- ${INSTALL} -s -f $? $@;; \
- *nbsd*) \
+ ${INSTALL_SCRIPT} ${srcdir}/kdump.sh.hp_ux11 ${DEST}/etc/kdump32; \
+ ${INSTALL_PROGRAM} kdump-build ${DEST}/etc/kdump ;; \
+ *bsd*) \
;; \
*) \
- ${INSTALL} -s $? $@ ;; \
+ ${INSTALL_PROGRAM} kdump-build ${DEST}/etc/kdump ;; \
esac
-
-${DEST}/etc/kdump64: kdump-build
- if [ -e kdump64 ]; then \
- ${INSTALL} -s kdump64 $@; \
+ if [ -f kdump64 ]; then \
+ ${INSTALL_PROGRAM} kdump64 ${DEST}/etc/kdump; \
fi
-
-#
-# Install targets
-#
-install: \
- ${DESTDIR}${bindir}/fs \
- ${DESTDIR}${bindir}/livesys \
- ${DESTDIR}${afssrvbindir}/fs \
- ${DESTDIR}${bindir}/up \
- ${DESTDIR}${sbindir}/fstrace \
- ${DESTDIR}${bindir}/cmdebug \
- ${DESTDIR}${sbindir}/kdump \
- ${DESTDIR}${sbindir}/kdump62
-
#
# Misc targets
#
clean:
- $(RM) -f *.o *.a up fs kdump-* kdump kdump64 core cmdebug AFS_component_version_number.c fstrace gcpags
+ $(RM) -f *.o *.a up fs kdump-* kdump kdump64 core cmdebug AFS_component_version_number.c fstrace gcpags livesys dedebug
test:
cd test; $(MAKE)
include ../config/Makefile.version
-
-${DESTDIR}${bindir}/fs: fs
- ${INSTALL} -s $? $@
-
-${DESTDIR}${bindir}/livesys: livesys
- ${INSTALL} -s $? $@
-
-${DESTDIR}${afssrvbindir}/fs: fs
- ${INSTALL} -s $? $@
-
-${DESTDIR}${bindir}/up: up
- ${INSTALL} -s $? $@
-
-${DESTDIR}${sbindir}/fstrace: fstrace
- ${INSTALL} -s $? $@
-
-${DESTDIR}${bindir}/cmdebug: cmdebug
- ${INSTALL} -s $? $@
-
-${DESTDIR}${sbindir}/kdump: kdump-build
- -set -x; \
- case ${SYS_NAME} in \
- sgi_6? ) \
- ${INSTALLex} -f kdump.sh.sgi_ipnos ${DESTDIR}${sbindir}/kdump; \
- ln -fs kdump ${DESTDIR}${sbindir}/kdump32; \
- ln -fs kdump.IP20 ${DESTDIR}${sbindir}/kdump.IP22; \
- ln -fs kdump.IP20 ${DESTDIR}${sbindir}/kdump.IP32; \
- for f in kdump.IP??; \
- do ${INSTALL} -s $$f ${DESTDIR}${sbindir}/$$f || exit $$? ; \
- done ;; \
- sun*_5[789] ) \
- ${INSTALLex} -f kdump.sh.solaris7 ${DESTDIR}${sbindir}/kdump32; \
- ${INSTALL} -s -f $? $@;; \
- *linux* ) \
- ${INSTALLex} -f kdump.sh.linux ${DESTDIR}${sbindir}/kdump; \
- ${INSTALL} -s $? $@ ;; \
- hp_ux11* ) \
- ${INSTALLex} -f kdump.sh.hp_ux11 ${DESTDIR}${sbindir}/kdump; \
- ${INSTALL} -s -f $? $@;; \
- *) \
- ${INSTALL} -s $? $@ ;; \
- esac
-
-${DESTDIR}${sbindir}/kdump64: kdump-build
- if [ -e kdump64 ]; then \
- ${INSTALL} -s kdump64 $@; \
- fi
-
-dest: \
- ${DEST}/bin/fs \
- ${DEST}/bin/livesys \
- ${DEST}/root.server/usr/afs/bin/fs \
- ${DEST}/bin/up \
- ${DEST}/etc/fstrace \
- ${DEST}/bin/cmdebug \
- ${DEST}/etc/kdump \
- ${DEST}/etc/kdump64
-